Veille CVE

‹ Retour à la liste

CVE-2026-111231

7.2 Élevée

Publiée le 15/10/2026 à 21:17 · Modifiée le 19/10/2026 à 22:42 · Analysée par le NVD · Source : disclosure@vulncheck.com

Description

Netgate pfSense CE through 2.9.0 contains an authorization bypass vulnerability that allows read-only WebGUI users to replace config.xml because config_restore() and config_install() ignore the 'User - Config: Deny Config Write' privilege. Attackers holding page privileges for services_acb.php, uploadconfig.php, diag_confbak.php, or diag_backup.php can install a chosen config.xml to gain root-level code execution after reload or reboot.

Traduire en français

Produits concernés

Scores CVSS

VersionScoreSourceVecteur
4.0 8.6 Élevée disclosure@vulncheck.com CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
3.1 7.2 Élevée disclosure@vulncheck.com (NVD) CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Faiblesses (CWE)

Références

Ailleurs