Veille CVE

‹ Retour à la liste

CVE-2025-30046

9.0 Critique

Publiée le 23/10/2026 à 11:17 · Modifiée le 23/10/2026 à 18:28 · Analyse NVD reportée · Source : cvd@cert.pl

Description

In the CGM CLININET application server, multiple processes responsible for HL7 communication with external systems run with root privileges while processing untrusted data received from those external systems. An attacker in adjacent network able to send data to these HL7 communication processes can achieve remote code execution with root privileges.  The vulnerability was confirmed to affect versions up to 2026.MS3 but later versions may also be vulnerable.

Traduire en français

Produits concernés

Scores CVSS

VersionScoreSourceVecteur
4.0 9.0 Critique cvd@cert.pl CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Faiblesses (CWE)

Références

Ailleurs