  1. CVE-2026-104610 10.0 Critique

    Tenda HG7 · Tenda HG9 · Tenda HG10

    A security vulnerability has been detected in Tenda HG7, HG9 and HG10 300001138_en_xpon. This impacts the function boaGetVar of the file /boaform/formLoopBack of the component Boa Web Server. Such manipulation of the argument Ethtype leads to stack-based buffer overflow. The attack can be executed remotely. The exploit has been disclosed publicly and may be used.

  2. CVE-2026-86167 9.9 Critique

    Tenda HG10

    A vulnerability was identified in Tenda HG10 300001138. Impacted is the function formgponConf of the file /boaform/admin/formgponConf of the component Boa. The manipulation of the argument fmgpon_loid leads to os command injection. Remote exploitation of the attack is possible. The exploit is publicly available and might be used.

  3. CVE-2026-86166 8.8 Élevée

    Tenda HG10

    A vulnerability was determined in Tenda HG10 300001138. This issue affects the function formWanRedirect of the file /boaform/formWanRedirect of the component Boa Web Server. Executing a manipulation of the argument if can lead to buffer overflow. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized.

  4. CVE-2026-86165 9.8 Critique

    Tenda HG10

    A vulnerability was found in Tenda HG10 300001138. This vulnerability affects the function formURL of the file /boaform/admin/formURL. Performing a manipulation of the argument Keywd/urlFQDN results in buffer overflow. The attack may be initiated remotely. The exploit has been made public and could be used.

  5. CVE-2026-85110 8.8 Élevée

    Tenda HG10

    A vulnerability was identified in Tenda HG10 300001138. Impacted is the function formWlanSetup of the file /boaform/formWlanSetup of the component Boa Web Server. The manipulation of the argument ssid leads to buffer overflow. Remote exploitation of the attack is possible. The exploit is publicly available and might be used.

  6. CVE-2026-85109 9.8 Critique

    Tenda HG10

    A vulnerability was determined in Tenda HG10 300001138. This issue affects the function formLogin of the file /boaform/formLogin of the component Boa Web Server. Executing a manipulation of the argument Username can lead to buffer overflow. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized.

  7. CVE-2026-82542 10.0 Critique

    Tenda HG10

    A weakness has been identified in Tenda HG10 300001138. Affected by this issue is the function formIPv6Routing of the file /boaform/admin/formIPv6Routing of the component Boa Web Server. This manipulation of the argument destNet causes buffer overflow. The attack is possible to be carried out remotely. The exploit has been made available to the public and could be used for attacks.

  8. CVE-2026-11553 8.8 Élevée

    Tenda HG7 · Tenda HG9 · Tenda HG10

    A vulnerability was found in Tenda HG7, HG9 and HG10 300001138_en_xpon. This affects the function formPPPEdit of the file /boaform/formPPPEdit. The manipulation of the argument encodename results in stack-based buffer overflow. The attack can be launched remotely. The exploit has been made public and could be used.

  9. CVE-2026-11499 9.8 Critique

    Tenda HG7 · Tenda HG9 · Tenda HG10

    A vulnerability was determined in Tenda HG7, HG9 and HG10 300001138_en_xpon. This affects the function formDOMAINBLK of the file /boaform/formDOMAINBLK. Executing a manipulation of the argument blkDomain can lead to stack-based buffer overflow. The attack may be performed from remote.

  10. CVE-2026-11498 8.8 Élevée

    Tenda HG7 · Tenda HG9 · Tenda HG10

    A vulnerability was found in Tenda HG7, HG9 and HG10 300001138_en_xpon. Affected by this issue is the function asp_voip_OtherSet of the file /boaform/voip_other_set of the component Web Management Interface. Performing a manipulation of the argument funckey_transfer results in stack-based buffer overflow. The attack is possible to be carried out remotely.

  11. CVE-2026-6988 8.8 Élevée

    Tenda HG10 · Tenda hg10 firmware

    A flaw has been found in Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon. This issue affects the function formRoute of the file /boaform/formRouting of the component Boa Service. This manipulation of the argument nextHop causes buffer overflow. It is possible to initiate the attack remotely. The exploit has been published and may be used.